Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Experimental test result performed using standard test guidelines
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
92.6 °C
Atm. press.:
974.8 hPa
Remarks on result:
other: No other detail available

Observation Table :

 Method Details    Observations  Remarks if, any
 Method

 The flash point of a flammable

liquid is the lowest temperature at

which there will be enough

flammable vapor to ignite when an

ignition source is applied.

                        
 Type of method  Closed cup  
Flash point apparatus

 Abel’s flash pt apparatus

Pensky-Martens flash point

apparatus

 

Pensky-Martens flash

point apparatus

Quantity of chemical

used

 g/ml

5ml 

Ignition source 

 Gas lighter/flame

 Gas lighter

 Atmospheric pressure

 hPa

 974.8 hPa

Mean Flash point

(RESULT)

 °C

 92.6 °C

Conclusions:
The flash point of the test substance was found to be 92.6°C at 974.8 hPa.
Executive summary:
A study was performed to determine the flash point of test chemical at atmospheric pressure. The study was conducted in accordance with ASTM Designation: D93–15a Standard Test Methods for Flash Point by Pensky-Marten’s Closed Cup Method . The mean flash point of was determined to be 92.6 °C at 974.8 hPa

Description of key information

The flashpoint of the test substance was determined to be 92.6°C at 974.8 hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
92.6 °C

Additional information

A study was performed to determine the flash point of test chemical at atmospheric pressure. The study was conducted in accordance with ASTM Designation: D93–15a Standard Test Methods for Flash Point by Pensky-Marten’s Closed Cup Method . The mean flash point of was determined to be 92.6 °C at 974.8 hPa