Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
04 October 2016 - 07 October 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
>= 211 - <= 215 °C
Atm. press.:
ca. 100.8 kPa
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test item has been determined to be 213 ± 2 °C.
Executive summary:

Flash Point. 213 ± 2°C, using a closed cup equilibrium method designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Description of key information

Flash Point. 213 ± 2°C, using a closed cup equilibrium method designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
213 °C

Additional information