Registration Dossier

Registration Dossier

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Basic data given (Certificate of Analysis)
Qualifier:
according to guideline
Guideline:
ASTM D-445 (Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity)
Qualifier:
according to guideline
Guideline:
ISO 3104 (Petroleum products - Transparent and opaque liquids - Determination of kinematic viscosity and calculation of dynamic viscosity)
GLP compliance:
no
Type of method:
capillary viscometer (static)
Key result
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
32.9
Remarks on result:
other: equal to cSt
Key result
Temp.:
other: 100.0°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
5.9
Remarks on result:
other: equal to cSt
Key result
Temp.:
other: -20.0°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
1 749
Remarks on result:
other: equal to cSt
Remarks:
mean value of three determinations

Description of key information

Kinematic viscosity: 32.9 mm2/s at 40 °C and 1749 mm2/s at -20 °C.

Key value for chemical safety assessment

Viscosity:
32.9 mm²/s (static)
at the temperature of:
40 °C

Additional information