Endpoint:
acute toxicity: oral
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is classified as corrosive to the skin
Justification for type of information:
JUSTIFICATION FOR DATA WAIVING
Based on the pH of 0.55 of the test substance (see reference 4.20-1), the test substance is classified as corrosive to the skin (H314). According to REACH Annex VII, 8.5 Column 2, no test for acute oral toxcicity is necessary.