Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Biodegradation in water: screening tests

Administrative data

Endpoint:
biodegradation in water: ready biodegradability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study; no deviations

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1999
Report date:
1999

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 301 B (Ready Biodegradability: CO2 Evolution Test)
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
1,4,6,10-Dodecatetraen-3-ol,3,7,11-trimethyl-,(4E,6E)-
EC Number:
611-799-6
Cas Number:
59121-99-2
Molecular formula:
C15H24O
IUPAC Name:
1,4,6,10-Dodecatetraen-3-ol,3,7,11-trimethyl-,(4E,6E)-
Test material form:
liquid: viscous
Details on test material:
- Name of test material (as cited in study report):Vinylpseudoionol
- Molecular formula (if other than submission substance): C15H24O
- Molecular weight (if other than submission substance): 220.36 g/mol
- Physical state: viscous-liquid
- Analytical purity: 87.1 %
- Impurities (identity and concentrations): 1.2 % water
- Purity test date: not indicated
- Lot/batch No.: technikumscharge M 401
- Expiration date of the lot/batch: not indicated
- Storage condition of test material: storage at room temperature under nitrogen
- Water solubility: poorly soluble

Study design

Oxygen conditions:
aerobic
Inoculum or test system:
sewage, domestic (adaptation not specified)
Details on inoculum:
Activated sludge from laboratory wastewater plants treating municipal sewage . Concentration of dry substance
30 mg/L
Duration of test (contact time):
28 d
Initial test substance concentrationopen allclose all
Initial conc.:
25 mg/L
Based on:
test mat.
Initial conc.:
20 mg/L
Based on:
other: TOC
Parameter followed for biodegradation estimation
Parameter followed for biodegradation estimation:
CO2 evolution
Details on study design:
TEST CONDITIONS
- Composition of medium:
- Additional substrate: no
- Test temperature: 20 - 25 °C
- pH: 7.0 - 7.4
- pH adjusted: yes
- Aeration of dilution water: yes (CO2 free air)
- Suspended solids concentration: 7.5 ml/L inoculum (6 g/l dry matter)
- Continuous darkness: yes/no
- Other:

TEST SYSTEM
- Culturing apparatus: brown glass bottles
- Number of culture flasks/concentration: 2 per test concentration, 1 per controls
- Test performed in open system: yes
- Details of trap for CO2 and volatile organics if used: CO2 trap according to OECD 301 B


SAMPLING
- Sampling days: 0, 1, 3, 5, 7, 10, 12 14, 17, 21, 24, 27, 29
- Sample storage before analysis: not relevant as the samples were analysed asap after sampling


CONTROL AND BLANK SYSTEM
- Inoculum blank: 1
- Abiotic sterile control: 1
- Toxicity control: 1


Reference substance
Reference substance:
aniline

Results and discussion

% Degradationopen allclose all
Parameter:
% degradation (CO2 evolution)
Value:
0 - 10
Sampling time:
3 d
Parameter:
% degradation (CO2 evolution)
Value:
10 - 20
Sampling time:
7 d
Parameter:
% degradation (CO2 evolution)
Value:
60
Sampling time:
12 d
Parameter:
% degradation (CO2 evolution)
Value:
60 - 70
Sampling time:
14 d
Parameter:
% degradation (CO2 evolution)
Value:
90 - 100
Sampling time:
27 d

BOD5 / COD results

Results with reference substance:
day 0: 0 %
day 3: -1 %
day 5: 27 %
day 14: 60 - 70 %
day 28: 70 - 80 %

Applicant's summary and conclusion