Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Surface tension

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
surface tension
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
from 2017-11-29 to 2018-07-19
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 115 (Surface Tension of Aqueous Solutions)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.5 (Surface Tension)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
ring method
Key result
Remarks on result:
not determinable

Based on the results of a solubility test the concentration of test solution suitable for surface tension measurement could not be determined. A solubility test at 1 mg/mL concentration level resulted an opalescent single-phase emulsion which is not suitable for the test.

Conclusions:
The test on surface tension is technically not feasible. No saturated test item solution could be prepared.
Executive summary:

Based on the results of a solubility test the concentration of test solution suitable for surface tension measurement could not be determined. A solubility test at 1 mg/mL concentration level resulted an opalescent single-phase emulsion which is not suitable for the test. Therefore, the test on surface tension is technically not feasible.

Endpoint:
surface tension
Data waiving:
study technically not feasible
Justification for data waiving:
other:

Description of key information

The test on surface tension is technically not feasible.

Key value for chemical safety assessment

Additional information

Based on the results of a solubility test the concentration of test solution suitable for surface tension measurement could not be determined. A solubility test at 1 mg/mL concentration level resulted an opalescent single-phase emulsion which is not suitable for the test. Therefore, the test on surface tension is technically not feasible.