Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
skin corrosion: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
The study was performed in compliance with the following regulations or guidelines:
• OECD Guideline for the Testing of Chemicals No. 431 In Vitro Skin Corrosion: Reconstructed Human EpiDermis (RHE) Test Method (28 July 2015).
• Method B.40bis of Commission Regulation (EC) No 440/2008, of 30 May 2008, laying down test methods pursuant to Regulation (EC) No 1907/2006 of the European Parliament and of the Council on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH).

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 431 (In Vitro Skin Corrosion: Reconstructed Human Epidermis (RHE) Test Method)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
617-898-0
EC Number:
617-898-0
Cas Number:
866462-52-4
Molecular formula:
C17 H21 N O5
IUPAC Name:
617-898-0
Test material form:
solid: particulate/powder
Details on test material:
Off white powder
Specific details on test material used for the study:
Batch 18108859 - Purity: 100.8%
Expiry Date: 01 March 2017
Storage Conditions: room temperature in the dark

In vitro test system

Test system:
human skin model
Source species:
human
Cell type:
non-transformed keratinocytes
Cell source:
foreskin from a single donor
Control samples:
yes, concurrent negative control

Test system

Controls:
yes, concurrent negative control

Results and discussion

In vitro

Resultsopen allclose all
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
3 min
Value:
ca. 102.5
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
60 min
Value:
ca. 102.4
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The test item was considered to be non-corrosive to the skin.
Executive summary:

The test item was considered to be non-corrosive to the skin.