Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
April 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
The determination was carried out by differential scanning calorimetry, using a procedure designed to be compatible with Method A.2 Boiling Temperature of Commission Regulation (EC) No 440/2008 of 30 May 2008 and Method 103 of the OECD Guidelines for Testing of Chemicals, 27 July 1995.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling Point)
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
GLP compliance:
yes (incl. QA statement)
Type of method:
differential scanning calorimetry

Test material

Constituent 1
Chemical structure
Reference substance name:
617-898-0
EC Number:
617-898-0
Cas Number:
866462-52-4
Molecular formula:
C17 H21 N O5
IUPAC Name:
617-898-0
Test material form:
solid: particulate/powder
Details on test material:
Off white powder
Specific details on test material used for the study:
Batch 18108859

Results and discussion

Boiling point
Key result
Atm. press.:
ca. 100.4 kPa
Decomposition:
yes
Decomp. temp.:
ca. 175 °C

Applicant's summary and conclusion

Conclusions:
The test item has been determined to decompose above 175 °C (448 K) at 100.4 kPa. As the test item decomposed, no value for boiling point could be determined.