Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Experimental test result performed using standard test guidelines
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
117 °C
Atm. press.:
976.6 hPa

Observation table:

Method Details

Observations

Remarks if, any

Method

Closed cup method

 

 

Principle of Flash point

test

The flash point of a flammable liquid is the lowest temperature at which there will be enough flammable vapor to ignite when an ignition source is applied.

 

 

Type of method

Closed cup

 

 

Flash point apparatus

·        Abel’s flash pt apparatus

·        Pensky-Martens flash point apparatus

 

 

Quantity of chemical

used

g/ml

5 ml

 

Ignition source

Gas lighter/flame

 

 

Atmospheric pressure

hPa

976.6hPa

 

Mean Flash point (RESULT)

°C

117°C

 

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point determination of test chemical was done by following closed cup method using Pensky-Martens flash point apparatus. The test was conducted in replicates and the mean flash point was determined to be 117°C at 976.6hPa.
Executive summary:

The flash point determination of test chemical was done by following closed cup method using Pensky-Martens flash point apparatus. The test was conducted in replicates and the mean flash point was determined to be 117°C at 976.6hPa.

Based on criteria mentioned in CLP regulation the chemical has flash point > 60 degree C hence it was considered to be non-flammable.

Description of key information

The flash point determination of test chemical was done by following closed cup method using Pensky-Martens flash point apparatus. The test was conducted in replicates and the mean flash point was determined to be 117°C at 976.6hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
117 °C

Additional information

The flash point determination of test chemical was done by following closed cup method using Pensky-Martens flash point apparatus. The test was conducted in replicates and the mean flash point was determined to be 117°C at 976.6hPa.

From the authoritative database flash point of the test substance was determined to be > 110 °C.

Thus, based on criteria mentioned in CLP regulation the chemical has flash point > 60 degree C hence it was considered to be non-flammable.