Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental starting date - 16 February 2017; Experimental completion date - 16 February 2017; Study completion date - 21 February 2017.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187: Particle Size Analysis by Laser Diffraction and ISO 13320-1: Particle Size Analysis – Laser Diffraction Methods
Deviations:
no
Principles of method if other than guideline:
As per the guideline
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
mass based distribution
Specific details on test material used for the study:
SOURCE AND DETAILS OF TEST MATERIAL
- Identification: FAT 31016/R
- Lot. AT003002200
- Appearance: Red powder
Mass median aerodynamic diameter:
ca. 89.256 µm
Key result
Percentile:
D50
Mean:
89.256 µm
Remarks on result:
other: L10: 11.590 μm; L50: 89.256 μm; L90: 395.024 μm
Conclusions:
The particle size distribution of the test substance was determined as follows: L10: 11.590 μm; L50: 89.256 μm; L90: 395.024
Executive summary:

A study was conducted wherein the particle size distribution of the test substance was evaluated according to the guidelines of CIPAC MT 187 and ISO 13320-1. The laser diffraction method was used for this purpose. The particle size distribution of the test substance was determined as follows: L10: 11.590 μm; L50: 89.256 μm; L90: 395.024 μm.

Description of key information

A study was conducted wherein the particle size distribution of the test substance was evaluated according to the guidelines of CIPAC MT 187 and ISO 13320-1. The laser diffraction method was used for this purpose. The particle size distribution of the test substance was determined as follows: L10: 11.590 μm; L50: 89.256 μm; L90: 395.024 μm.

Additional information