Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2003-01-14
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Qualifier:
equivalent or similar to guideline
Guideline:
DIN EN 15188 (Determination of the spontaneous ignition behaviour of dust accumulations)
Principles of method if other than guideline:
Deposited dust: This test determines the ignition temperature of a dry product on a hot surface. For a description of the method see "any other information on materials and methods".
GLP compliance:
not specified
Key result
Relative self-ignition temperature:
> 360 °C
Remarks on result:
no self ignition observed under the test conditions

At the highest tested temperature (360°C) there was no reaction observed for deposited TDI-Urone dust.

Conclusions:
No auto-ignition of deposited TDI-Urone dust occurred on surfaces until 360°C.
Executive summary:

The test determines the ignition temperature of a deposited dusty test substance on hot surfaces. The test is conducted according to the test protocol. The surface area of the substance is increased intentionally in this test by preparing the test substance accordingly to simulate the deposited dusty properties. The ignition temperature of deposited dusty test material is expected to be lower than the ignition temperature of the solid with larger particle diameters. At the hottest temperature in this test (360°C) there was no reaction observed for deposited TDI-Urone dust.

Endpoint:
self-ignition of dust accumulation
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
2003-01-14
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Qualifier:
equivalent or similar to guideline
Guideline:
DIN EN 15188 (Determination of the spontaneous ignition behaviour of dust accumulations)
Principles of method if other than guideline:
Dispersed dust: This test determines the ignition temperature of flammable dispersed dusty substances on hot surfaces. See section "any other information on materials and methods" for detailed description of the method.
GLP compliance:
not specified
Key result
Self-ignition temperature:
>= 435

The lowest temperature at which ignition of dispersed TDI-Urone dust was observed was 435°C.

Conclusions:
The lowest temperature at which ignition of dispersed TDI-Urone dust was observed was 435°C.
Executive summary:

The test determines the ignition temperature of a dispersed dusty test substance on hot surfaces. The test is conducted according to a test protocol. The surface area of the substance is increased intentionally in this test by preparing the test substance accordingly to simulate the dispersed dusty properties. The ignition temperature of dispersed dusty test material is expected to be significantly lower than the ignition temperature of the solid with larger particle diameters. The lowest temperature at which ignition of dispersed TDI-Urone dust was observed was 435°C.

Description of key information

Two tests for dusty TDI-Urone are available evaluating the auto-flammability on hot surface for deposited and dispersed TDI-Urone with particle diameter of 0.25 mm. No auto-ignition of deposited TDI-Urone dust occurred on surfaces until 360°C.
The lowest temperature at which ignition of dispersed TDI-Urone dust was observed was 435°C.

Key value for chemical safety assessment

Additional information

The test for deposited TDI-Urone (100 mg) was conducted for 5 min on a hot surface up to 360°C. No reaction was observed.

The test for dispersed TDI-Urone was conducted on a surface up to 600°C. The lowest temperature at which ignition of dispersed TDI-Urone dust was observed was 435°C.

As the tests were conducted with smaller particle diameters due to grinding and sieving the tested dusty TDI-Urone is expected to react even more sensible with regard to auto-flammability as original TDI-Urone produced directly from the operating facilities. Therefore it is concluded that the self-ignition temperature of TDI-Urone is higher than 360°C. This temperature is higher than the melting point (approx. 185°C). Thus TDI-Urone melts before it is self-ignited.