Registration Dossier

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2013
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Flammability test performed based on national standard VDI2263/Clariant internal method

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report Date:
2013

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: VDI- Richtlinie 2263 (national standard)
Principles of method if other than guideline:
A sample in a pile form is ignited using a flame and an electrically heated Platinum wire and the burning behaviour was observed.
GLP compliance:
not specified

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flammable solids
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
other: No burning when contacted by a flame or heated platinum wire.

Any other information on results incl. tables

No burning when contacted by a flame or heated platinum wire. Therefore the measurement of the burning rate is technically not feasible and needed.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Conclusions:
No classification as flammable solid.