Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Jan 27, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
no

Test material

Constituent 1
Reference substance name:
Fatty acids, C16-18 and C18-hydroxy, oligomeric reaction products with adipic acid, decanoic acid, isooctadecanoic acid, octanoic acid, pentaerythritol and stearic acid
EC Number:
500-320-5
EC Name:
Fatty acids, C16-18 and C18-hydroxy, oligomeric reaction products with adipic acid, decanoic acid, isooctadecanoic acid, octanoic acid, pentaerythritol and stearic acid
Cas Number:
130353-58-1
Molecular formula:
not applicable, the substance is UVCB
IUPAC Name:
1,6-bis({2-[(hexadecanoyloxy)methyl]-3-hydroxy-2-(hydroxymethyl)propyl}) hexanedioate; 1-{2-[(decanoyloxy)methyl]-3-hydroxy-2-[(octadecanoyloxy)methyl]propyl} 6-[3-hydroxy-2-(hydroxymethyl)-2-{[(3-methylheptadecanoyl)oxy]methyl}propyl] hexanedioate; 3-hydroxy-2-{[(6-{[3-hydroxy-2-(hydroxymethyl)-2-[(octadecanoyloxy)methyl]propyl]peroxy}-6-oxohexanoyl)oxy]methyl}-2-(hydroxymethyl)propyl 12-hydroxyoctadecanoate

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
0 s
Remarks on result:
other: The flame extinguishes shortly after the gas burner is removed.

Any other information on results incl. tables

The test item was formed into a particle train. A hot flame from a gas burner with a diameter of about 6 mm is used to ignite the pile at one end. In the preliminary screening test the substance ignites by a hot flame from a gas burner. The flame extinguishes shortly after the gas burner is removed. According to the definition in the Council Regulation (EC) No 440/2008 that is pursuant to Regulation (EC) No 1907/2006 the test item is not considered as flammable.

Applicant's summary and conclusion

Conclusions:
According to the definition in the Council Regulation (EC) No 440/2008 that is pursuant to Regulation (EC) No 1907/2006 the test item is not considered as flammable.