Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Flash point:
ca. 135 °C
Atm. press.:
ca. 101.2 kPa

During the test, the ambient temperature was 25℃, the barometric pressure was 101.2 kPa;

The expected flash point obtained from the preliminary test, was 140℃.

Conclusions:
The flash point could be confirmed:135.0°C (101.2 kPa).

Description of key information

Key value for chemical safety assessment

Flash point at 101 325 Pa:
135 °C

Additional information