First-aid measures

--- Description of first aid measures ---
-General advice :
Move out of dangerous area.
Show the safety data sheet to the doctor in attendance.
Symptoms of poisoning may appear several hours later.
Do not leave the victim unattended.

-If inhaled:
Move to fresh air.
If unconscious place in recovery position and seek medical advice.
If symptoms persist, call a physician.

-In case of skin contact :
If on skin, rinse well with water.
If on clothes, remove clothes.

-In case of eye contact :
Flush eyes with water as a precaution.
Remove contact lenses.
Protect unharmed eye.
Keep eye wide open while rinsing.
If eye irritation persists, consult a specialist.

-If swallowed :
Keep respiratory tract clear.
Do NOT induce vomiting.
Do not give milk or alcoholic beverages.
Never give anything by mouth to an unconscious person.
Take victim immediately to hospital.

--- Most important symptoms and effects, both acute and delayed ---
Symptoms : no data available
Risks : no data available

--- Indication of any immediate medical attention and special treatment needed ---
Treatment : no data available

Fire-fighting measures

--- Extinguishing media ---
Suitable extinguishing media :
Dry chemical.
Alcohol-resistant foam .
Carbon dioxide (CO2).
Water spray.

Unsuitable extinguishing media :
no data available

--- Special hazards arising from the substance or mixture ---
Specific hazards during firefighting :
Do not allow run-off from fire fighting to enter drains or water courses.

--- Advice for firefighters ---
-Special protective equipment for firefighters :
In the event of fire, wear self-contained breathing apparatus.

-Further information :
Collect contaminated fire extinguishing water separately. This must not be discharged into drains.
Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations.
For safety reasons in case of fire, cans should be stored separately in closed containments.
Use a water spray to cool fully closed containers.

Accidental release measures

--- Personal precautions, protective equipment and emergency procedures ---
-Personal precautions :
Use personal protective equipment.
Ensure adequate ventilation.
Remove all sources of ignition.
Evacuate personnel to safe areas.
Beware of vapours accumulating to form explosive concentrations. Vapours can accumulate in low areas.

--- Environmental precautions ---
Environmental precautions :
Prevent product from entering drains.
Prevent further leakage or spillage if safe to do so.
If the product contaminates rivers and lakes or drains inform respective authorities.

--- Methods and materials for containment and cleaning up ---
Methods for cleaning up:
Contain spillage, and then collect with non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and place in container for disposal according to local / national regulations.

--- Reference to other sections ---
Not applicable.

Handling and storage

--- Precautions for safe handling ---
-Advice on safe handling :
Do not breathe vapours/dust.
Avoid exposure - obtain special instructions before use.
Avoid contact with skin and eyes.
For personal protection see section 8 of SDS.
Smoking, eating and drinking should be prohibited in the application area.
Take precautionary measures against static discharges.
Provide sufficient air exchange and/or exhaust in work rooms.
Open drum carefully as content may be under pressure.
Dispose of rinse water in accordance with local and national regulations.

-Advice on protection against fire and explosion :
Do not spray on a naked flame or any incandescent material.
Take necessary action to avoid static electricity discharge (which might cause ignition of organic vapours).
Keep away from open flames, hot surfaces and sources of ignition.

-Temperature class : no data available
-Fire-fighting class : no data available
-Dust explosion class : no data available

--- Conditions for safe storage, including any incompatibilities ---
-Requirements for storage areas and containers :
No smoking.
Keep container tightly closed in a dry and well-ventilated place.
Containers which are opened must be carefully resealed and kept upright to prevent leakage.
Electrical installations / working materials must comply with the technological safety standards.

-Further information on storage conditions :
No data available.

-Advice on common storage :
No data available.

-German storage class :
No data available.

-Other data :
No decomposition if stored and applied as directed.

--- Specific use(s) ---
Specific use(s) :
No data available

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
3295
Shipping information
Proper shipping name and description:
HYDROCARBONS, LIQUID, N.O.S.
Language:
English
Labels:
3
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
3295
Shipping information
Proper shipping name and description:
HYDROCARBONS, LIQUID, N.O.S.
Language:
English
Labels:
3
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
3295
Shipping information
Proper shipping name and description:
HYDROCARBONS, LIQUID, N.O.S.
Chemical name:
Methyl isopropenyl cyclohexene
Labels:
3
Marine pollutant
Special provisions / remarks
Remarks:
Methyl isopropenyl cyclohexene

Air transport (UN RTDG/ICAO/IATA)

UN number:
3295
Shipping information
Proper shipping name and description:
Hydrocarbons, liquid, n.o.s.
Labels:
3
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

--- Control parameters ---
Contains no substances with occupational exposure limit values.

--- Exposure controls ---
-Personal protective equipment
Hand protection :
The suitability for a specific workplace should be discussed with the producers of the protective gloves.

Eye protection :
Eye wash bottle with pure water.
Tightly fitting safety goggles.

Skin and body protection:
Impervious clothing.
Choose body protection according to the amount and concentration of the dangerous substance in the workplace.

Hygiene measures :
When using do not eat or drink.
When using do not smoke.
Wash hands before breaks and at the end of the workday.

-Environmental exposure controls
General advice :
Prevent further leakage or spillage if safe to do so.
If the product contaminates rivers and lakes or drains inform respective authorities.

Stability and reactivity

--- Reactivity ---
none

--- Chemical stability ---
The product is chemically stable.

--- Possibility of hazardous reactions ---
Hazardous reactions :
No decomposition if stored and applied as directed.Vapours may form explosive mixture with air.

--- Conditions to avoid ---
Conditions to avoid : Heat, flames and sparks.

--- Incompatible materials ---
Materials to avoid : no data available

--- Hazardous decomposition products ---
Hazardous decomposition products : no data available
Thermal decomposition : no data available

Disposal considerations

---Waste treatment methods ---
-Product :
The product should not be allowed to enter drains, water courses or the soil.
Do not contaminate ponds, waterways or ditches with chemical or used container.
Send to a licensed waste management company.

-Contaminated packaging :
Empty remaining contents.
Dispose of as unused product.
Do not re-use empty containers.
Do not burn, or use a cutting torch on, the empty drum.

-Dispose of in accordance with local regulations.