Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 230-811-7 | CAS number: 7328-17-8
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Hydrolysis
Administrative data
Link to relevant study record(s)
- Endpoint:
- hydrolysis
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 02 March 2017 - 28 May 2017
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 111 (Hydrolysis as a Function of pH)
- Version / remarks:
- 13. April 2004
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method C.7 (Degradation: Abiotic Degradation: Hydrolysis as a Function of pH)
- Version / remarks:
- No 440/2008 of 30 May 2008
- Deviations:
- no
- Principles of method if other than guideline:
- NA
- GLP compliance:
- yes (incl. QA statement)
- Specific details on test material used for the study:
- Identification: Ethoxy ethoxy ethyl acrylate CAS No. 7328-17-8
Appearance/Physical state: Clear colorless liquid
Lot: 151210177
Purity: 95.49%
Expiry date: 30 June 2017
Storage conditions: Room temperature, in the dark - Radiolabelling:
- no
- Analytical monitoring:
- yes
- Details on sampling:
- Analysis of the Sample Solutions
The sample solutions were taken from the water bath at various times and the pH of each solution recorded. The concentration of the sample solutions was determined by gas chromatography (GC).
Samples:
For the initial time point, duplicate aliquots of each test solution were diluted by a factor of 4 using acetonitrile.
For the incubated samples, an aliquot of each sample solution (duplicate vessels A and B being removed at each time point) was diluted by a factor of 4 using acetonitrile.
Standards:
Duplicate standard solutions of test item were prepared in 75:25 v/v acetonitrile:relevant buffer solution at a nominal concentration of 250 mg/L.
Matrix blanks:
75:25 v/v acetonitrile:relevant buffer solution. - Buffers:
- Specification of the Buffer Solutions
pH=4
Potassium hydrogen phthalate 0.05 mol/dm3
Citric acid; 0.06 mol/dm3
Sodium chloride; 0.04 mol/dm3
Sodium hydroxide; 0.07 mol/dm3
pH=7
Disodium hydrogen orthophosphate (anhydrous); 0.03 mol/dm3
Potassium dihydrogen orthophosphate; 0.02 mol/dm3
Sodium chloride; 0.02 mol/dm3
pH=9
Disodium tetraborate; 0.01 mol/dm3
Sodium chloride; 0.02 mol/dm3
The buffer solutions were subjected to filtration through 0.2 μm filters, ultrasonication and degassing with nitrogen to minimize dissolved oxygen content. - Details on test conditions:
- Preliminary Test (Tier 1):
Sample solutions at pH 4, pH 7 and pH 9 were maintained at 50.0 ± 0.5 °C for the following periods of time: 120 h for the pH 4 samples, 672 h for the pH 7 samples and 22 h for the pH 9 samples.
Duplicate, independently incubated samples were removed for analysis at each time point, for each pH value.
Tier 2:
Results from the Preliminary Test/Tier 1 showed it was necessary to undertake further testing at pH 7 and pH 9. Sample solutions were maintained at 60.0 ± 0.5 °C for the following periods of time: 262 h for the pH 7 samples and 7 h for the pH 9 samples. Sample solutions were also maintained 96.5 h at 70.0 ± 0.5 °C for the pH 7 samples and 46.6 h at 40.0 ± 0.5 °C for the pH 9 samples.
Duplicate, independently incubated samples were removed for analysis at each time point, for both pH values
Test item (0.1007 g) was diluted to 100 mL with methanol. The solution was then diluted by a factor of 2 with methanol to give a concentration of 504 mg/L. - Duration:
- 120 h
- pH:
- 4
- Temp.:
- 50 °C
- Initial conc. measured:
- 1 g/L
- Remarks:
- tier 1
- Duration:
- 672 h
- pH:
- 7
- Temp.:
- 50 °C
- Initial conc. measured:
- 1 g/L
- Remarks:
- tier 1
- Duration:
- 22 h
- pH:
- 9
- Temp.:
- 50 °C
- Initial conc. measured:
- 1 g/L
- Remarks:
- tier 1
- Duration:
- 262 h
- pH:
- 7
- Temp.:
- 60 °C
- Initial conc. measured:
- 1 g/L
- Remarks:
- tier 2
- Duration:
- 7 h
- pH:
- 9
- Temp.:
- 60 °C
- Initial conc. measured:
- 1 g/L
- Remarks:
- tier 2
- Duration:
- 96.5 h
- pH:
- 7
- Temp.:
- 70 °C
- Initial conc. measured:
- 1 g/L
- Remarks:
- tier 2
- Duration:
- 46.6 h
- pH:
- 9
- Temp.:
- 40 °C
- Initial conc. measured:
- 1 g/L
- Remarks:
- tier 2
- Number of replicates:
- 2
- Positive controls:
- not specified
- Negative controls:
- not specified
- Statistical methods:
- NA
- Transformation products:
- not measured
- Key result
- pH:
- 4
- Temp.:
- 25 °C
- DT50:
- > 1 yr
- Type:
- (pseudo-)first order (= half-life)
- Remarks on result:
- hydrolytically stable based on preliminary test
- Key result
- pH:
- 7
- Temp.:
- 25 °C
- Hydrolysis rate constant:
- 0 h-1
- DT50:
- 313 d
- Type:
- (pseudo-)first order (= half-life)
- Remarks on result:
- hydrolytically stable based on preliminary test
- Key result
- pH:
- 9
- Temp.:
- 25 °C
- Hydrolysis rate constant:
- 0.006 h-1
- DT50:
- 4.65 d
- Type:
- (pseudo-)first order (= half-life)
- Remarks on result:
- hydrolytically stable based on preliminary test
- Validity criteria fulfilled:
- yes
- Executive summary:
The hydrolytic stability of Ethoxy ethoxy ethyl acrylate (CAS No. 7328-17-8) was determined using a procedure designed to be compatible with Method C.7 Abiotic Degradation, Hydrolysis as a Function of pH of Commission Regulation (EC) No 440/2008 of 30 May 2008 and Method 111 of the OECD Guidelines for Testing of Chemicals, 13 April 2004.
Duplicate samples (standard, sample and blank solutions) were analyzed by gas chromatography with flame ionization detection (GC-FID).
The linearity of the detector response with respect to concentration was assessed over the nominal concentration range of 10 to 300 mg/L in 75:25 v/v acetonitrile:relevant buffer
solution. This was satisfactory with a goodness of fit coefficient (r2) of 1.000 being obtained for all three matrices. The kinetics of the study have been determined to be consistent with that of a pseudo-first order reaction, as the graphs of log10 concentration versus time are straight lines.
The estimated rate constants at 25 °C was not applicable (pH 4), 9.22 x 10-5 h-1 (pH 7) and 6.21 x 10-3 h-1 (pH 9). The coresponding half-lives at 25 °C >1 year (pH 4), 313 days (pH 7) and 4.65 days (pH 9). Based on these results, the rate of hydrolysis increases with an increase in pH, with Ethoxy ethoxy ethyl acrylate (CAS No. 7328-17-8) being hydrolytically stable at pH 4.
Reference
The linearity of the detector response with respect to concentration was assessed over the nominal concentration range of 10 to 300 mg/L in 75:25 v/v acetonitrile:relevant buffer solution. This was satisfactory with a goodness of fit coefficient (r2) of 1.000 being obtained for all three matrices.
In most sequences, the analysis of the matrix blank solutions showed a small peak at the approximate retention time of the test item. The peak decreased significantly or even disappeared in the second injection of the blank solution, suggesting that it was caused by carryover. It has to be noted that this carryover did not exceed 10% of the sample response and affected both standard and sample solutions. It has therefore been considered that its overall effect on the results was negligible.
The kinetics of the study have been determined to be consistent with that of a pseudo-first order reaction, as the graphs of log10 concentration versus time are straight lines.
It has been observed that the rate of hydrolysis increases with an increase in pH, with the test item being hydrolytically stable at pH 4.
Description of key information
The estimated rate constants and half-lives at 25 °C of the test item are found at:
pH |
Estimated rate constant at 25 °C |
Estimated half-life at 25 °C |
4 |
Not applicable |
>1 year |
7 |
9.22 x 10-5h-1 |
313 days |
9 |
6.21 x 10-3h-1 |
4.65 days |
Key value for chemical safety assessment
- Half-life for hydrolysis:
- 313 d
- at the temperature of:
- 25 °C
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.

EU Privacy Disclaimer
This website uses cookies to ensure you get the best experience on our websites.