Administrative data

Endpoint:
surface tension
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 2017-09-06 to 2017-11-02
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.5 (Surface Tension)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 115 (Surface Tension of Aqueous Solutions)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: DIN EN 14370 Bestimmung der Oberflächenspannung; Novem-ber 2004
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
ring method

Test material

Constituent 1
Chemical structure
Reference substance name:
5-[(2-hydroxyethyl)amino]-o-cresol
EC Number:
259-583-7
EC Name:
5-[(2-hydroxyethyl)amino]-o-cresol
Cas Number:
55302-96-0
Molecular formula:
C9H13NO2
IUPAC Name:
5-[(2-hydroxyethyl)amino]-2-methylphenol
Test material form:
solid: particulate/powder
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 1-I00931
- Expiration date of the lot/batch: 2019-02-01
- Purity test date: 2017-02-03

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: At 20 °C ± 5 °C, in the dark (Stored in tightly closed containers in cool, dry, well-ventilated area)
- Stability under test conditions: not reported

TREATMENT OF TEST MATERIAL PRIOR TO TESTING no

Results and discussion

Surface tension
Key result
Surface tension:
71.9 mN/m
Temp.:
20 °C
Conc.:
1 g/L

Any other information on results incl. tables

Surface Tension of Water: 72.8 mN/m at 20 °C ± 0.5 °C

Calibration Factor: The calibration factor was calculated to be: 72.8 mN/m73.1 mN/m=0.996

Remark: The test item which lowers the surface tension of the medium in which it is dissolved, and/or the interfacial tension with other phases, and, accordingly, is positively adsorbed at the liquid/vapour and/or at other interfaces - is a surface active test item.

Measured Surface Tension of the Test Item

 
 Measurement n°  Time expired (min)  Temperature (°C)  Surface tension measured (mN/m)  Suface tension corrected 1 (mN/m) Surface tension corrected 2 (mN/m) 
 1  0  20.5  72.2    
 2  15  20.0  72.2    
 3  30  19.5  72.4    
 4  45  19.5  72.3    
 5  60  19.5  72.2    
     mean value (n=5) 72.3   72.0

 71.9

1: corrected for the calibration factor (water): factor: 0.996

2: corrected by Harkins-Jordan-regression (y=0.7232*xE+1.0756)          

Applicant's summary and conclusion

Conclusions:
The surface tension of an aqueous solution of the test item (1 g/L) was determined to be: 71.9 mN/m at 20 °C ± 0.5 °C.
Executive summary:

The purpose of the study was to determine the surface tension of an aqueous solution of the test item (1 g/L) by means of a ring tensiometer according to OECD 115 guideline and A.5 method following GLP. The surface tension of an aqueous solution of the test item (1 g/L) was determined to be: 71.9 mN/m at 20 °C ± 0.5 °C.