Registration Dossier

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Version / remarks:
2015
Deviations:
no
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
2008
Deviations:
no
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: particulate/powder
Remarks:
white powder

Results and discussion

Flammable solids
Test procedure:
burning rate test: preliminary screening test
Burning time:
> 4 min

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The preliminary screening test was performed for the determination of the flammability of Barium bromide.
No propagation of combustion of the test item along 200 mm length of the pile within
4 minutes was observed. According to the guidelines, performance of the burning rate test is not required. Based on the results obtained, the test item is considered ‘not highly flammable’.