Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
November - December 2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
TEST MATERIAL
- Substance identification/name in the report: LZ 596
- Molecular formula: C21H30N2
- Batch no.: 1229
- Analysis date: August 12, 2014
- Date of production: August 11, 2014

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage conditions: Controlled room temperature (15-25 ºC, below 70 RH%), protected from light and humidity.
- Stability under test conditions: stable for min. 3 years from manufacturing date
- Expiry date: August 10, 2017
- Safety precautions: Routine safety precautions (lab coat, gloves, safety glasses, face mask) for unknown materials were applied to assure personnel health and safety.
Key result
Relative self-ignition temperature:
> 120 °C

No ignition was observed up to melting point (88.7 °C) and up to temperature 120 °C.

Conclusions:
No ignition was observed up to melting point (88.7 °C) and up to temperature 120 °C. Therefore, the relative self-ignition temperature is > 120°C.
Executive summary:

The test was conducted according to EU testing method A.16. The measured self-ignition temperature of the test item was > 120°C.

Description of key information

The test was conducted according to EU testing method A.16. The measured self-ignition temperature of the test item was > 120°.

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
120 °C

Additional information

Source: GLP-report