Registration Dossier

Administrative data

Endpoint:
oxidising properties, other
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because there are no chemical groups present in the molecule which are associated with oxidising properties and hence, the classification procedure does not need to be applied

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.17 (Oxidising Properties (Solids))
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: flakes

Results and discussion

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
substance and cellulose in a 4:1 or 1:1 sample-to-cellulose ratio (by mass) is less than or equal to the
mean burning time of a 3:7 reference mixture (by mass) of potassium bromate and cellulose.
The main component and the identified impurities do not contain groups that might act as an oxidizing agent. The oxygen atoms that are
present in the molecular structure of the test substance are chemically bonded to carbon or hydrogen.
In conclusion, 852 IMIDE BRUTE has no oxidizing properties.