Registration Dossier

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Cross-reference
Reason / purpose:
reference to same study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report Date:
2010

Materials and methods

Test guidelineopen allclose all
Qualifier:
equivalent or similar to
Guideline:
EU Method A.2 (Boiling Temperature)
Qualifier:
equivalent or similar to
Guideline:
other: ASTM Method D1120
GLP compliance:
yes
Type of method:
ebulliometer

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Purity: not reported as such

Results and discussion

Boiling point
Key result
Decomposition:
yes
Decomp. temp.:
160 °C
Remarks on result:
other: decomposition evidenced by a colour change at approximately 160°C

Applicant's summary and conclusion

Conclusions:
The test substance decomposes at approximately 160°C
Executive summary:

The boiling point was determined in accordance with methods similar to EC Method A.2. The test substance decomposes at approximately 160°C