Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 946-381-5 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Eye irritation
Administrative data
- Endpoint:
- eye irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 24 Feb 2017 to 28 Feb 2017
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 017
- Report date:
- 2017
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage)
- Version / remarks:
- July 26, 2013
- GLP compliance:
- yes
Test material
- Reference substance name:
- CAS/EC/IUPAC not yet assigned
- IUPAC Name:
- CAS/EC/IUPAC not yet assigned
- Test material form:
- liquid
Constituent 1
- Specific details on test material used for the study:
- SOURCE OF TEST MATERIAL
- Source of test material: Zschimmer and Schwarz GmbH + Co. KG.
- Identification: 0125 SCHWEFELSÄURE, MIPA-SALZ
- Batch: CH 220612
- Purity/Composition: UVCB
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Test item storage: At room temperature
- Stable under storage conditions until: 07 December 2017 (expiry date)
OTHER SPECIFICS
- Appearance: Yellow turbid liquid
Test animals / tissue source
- Species:
- cattle
- Strain:
- other: bovine
- Details on test animals or tissues and environmental conditions:
- TEST SYSTEM
- Test system: Bovine eyes were used as soon as possible after slaughter.
- Rationale: In the interest of sound science and animal welfare, a sequential testing strategy is recommended to minimize the need of in vivo testing. As a consequence a validated and accepted in vitro test for eye irritation should be performed before in vivo tests are conducted. One of the proposed validated in vitro eye irritation tests is the Bovine Corneal Opacity and Permeability (BCOP) test.
- Source: Bovine eyes from young cattle were obtained from the slaughterhouse (Vitelco, 's Hertogenbosch, The Netherlands), where the eyes were excised by a slaughterhouse employee as soon as possible after slaughter.
- Transport: Eyes were collected and transported in physiological saline in a suitable container under cooled conditions.
Test system
- Vehicle:
- unchanged (no vehicle)
- Controls:
- yes, concurrent positive control
- yes, concurrent negative control
- Amount / concentration applied:
- TEST MATERIAL AND CONCURRENT CONTROLS
750 µL of either the negative control, positive control (Ethanol) or test item was introduced onto the epithelium of the cornea. - Duration of treatment / exposure:
- 10 ± 1 minutes
- Duration of post- treatment incubation (in vitro):
- 120 ± 10 minutes
- Number of animals or in vitro replicates:
- 3
- Details on study design:
- PREPARATION OF CORNEAS
- The eyes were checked for unacceptable defects, such as opacity, scratches, pigmentation and neovascularization by removing them from the physiological saline and holding them in the light. Those exhibiting defects were discarded.
- The isolated corneas were stored in a petri dish with cMEM (Earle’s Minimum Essential Medium (Life Technologies, Bleiswijk, The Netherlands) containing 1% (v/v) L-glutamine (Life Technologies) and 1% (v/v) Foetal Bovine Serum (Life Technologies)). The isolated corneas were mounted in a corneal holder (one cornea per holder) of BASF (Ludwigshafen, Germany) with the endothelial side against the O-ring of the posterior half of the holder. The anterior half of the holder was positioned on top of the cornea and tightened with screws. The compartments of the corneal holder were filled with cMEM of 32 ± 1°C. The corneas were incubated for the minimum of 1 hour at 32 ± 1°C.
CORNEA SELECTION AND OPACITY READING
After the incubation period, the medium was removed from both compartments and replaced with fresh cMEM. Opacity determinations were performed on each of the corneas using an opacitometer (BASF-OP3.0, BASF, Ludwigshafen, Germany). The opacity of each cornea was read against a cMEM filled chamber, and the initial opacity reading thus determined was recorded. Corneas that had an initial opacity reading higher than 7 were not used. Three corneas were selected at random for each treatment group.
TEST ITEM PREPARATION
The purity of the test item is 75.1%; the remainder is water. A correction factor is not applicable for the BCOP test, therefore no correction was made for the purity of the test item. The test item was tested neat.
TREATMENT OF CORNEAS AND OPACITY MEASUREMENTS
Due to a technical error, the first experiment was aborted and a repeat assay was performed. The medium from the anterior compartment was removed and 750 µL of either the negative control, positive control (Ethanol) or test item was introduced onto the epithelium of the cornea. The holders were slightly rotated, with the corneas maintained in a horizontal position, to ensure uniform distribution of the control or the test item over the entire cornea. Corneas were incubated in a horizontal position for 10 ± 1 minutes at 32 ± 1°C. After the incubation the solutions were removed and the epithelium was washed with MEM with phenol red (Earle’s Minimum Essential Medium, Life Technologies) and thereafter with cMEM. Possible pH effects of the test item on the corneas were recorded. The medium in the posterior compartment was removed and both compartments were refilled with fresh cMEM. Subsequently the corneas were incubated for 120 ± 10 minutes at 32 ± 1°C. After the completion of the incubation period opacity determination was performed. Each cornea was inspected visually for dissimilar opacity patterns.
OPACITY MEASUREMENT
- The opacity of a cornea was measured by the diminution of light passing through the cornea. The light was measured as illuminance (I = luminous flux per area, unit: lux) by a light meter.
- The opacity value (measured with the device OP-KIT) was calculated according to:
Opacity=[ I(0) / I - 0.9894] / 0.0251
With I(0) the empirically determined illuminance through a cornea holder but with windows and medium, and I the measured illuminance through a holder with cornea.
- The change in opacity for each individual cornea (including the negative control) was calculated by subtracting the initial opacity reading from the final post-treatment reading. The corrected opacity for each treated cornea with the test item or positive control was calculated by subtracting the average change in opacity of the negative control corneas from the change in opacity of each test item or positive control treated cornea.
- The mean opacity value of each treatment group was calculated by averaging the corrected opacity values of the treated corneas for each treatment group.
APPLICATION OF SODIUM FLUORESCEIN
- Following the final opacity measurement, permeability of the cornea to Na-fluorescein (Sigma-Aldrich, Germany) was evaluated.
- The medium of both compartments (anterior compartment first) was removed. The posterior compartment was refilled with fresh cMEM. The anterior compartment was filled with 1 mL of 4 mg Na-fluorescein (Sigma-Aldrich Chemie GmbH, Germany)/ml cMEM solution. The holders were slightly rotated, with the corneas maintained in a horizontal position, to ensure uniform distribution of the sodium-fluorescein solution over the entire cornea. Corneas were incubated in a horizontal position for 90 ± 5 minutes at 32 ± 1°C.
PERMEABILITY DETERMINATIONS
- After the incubation period, the medium in the posterior compartment of each holder was removed and placed into a sampling tube labelled according to holder number. 360 µL of the medium from each sampling tube was transferred to a 96-well plate. The optical density at 490 nm (OD490) of each sampling tube was measured in triplicate using a microplate reader (TECAN Infinite® M200 Pro Plate Reader). Any OD490 that was 1.500 or higher was diluted to bring the OD490 into the acceptable range (linearity up to OD490 of 1.500 was verified before the start of the experiment). OD490 values of less than 1.500 were used in the permeability calculation.
- The mean OD490 for each treatment was calculated using cMEM corrected OD490 values. If a dilution has been performed, the OD490 of each reading of the positive control and the test item was corrected for the mean negative control OD490 before the dilution factor was applied to the reading.
ACCEPTABILITY CRITERIA
The assay is considered acceptable if:
- The positive control gives an in vitro irritancy score that falls within two standard deviations of the current historical mean.
- The negative control responses should result in opacity and permeability values that are less than the upper limits of the laboratory historical range.
INTERPRETATION
- The mean opacity and mean permeability values (OD490) were used for each treatment group to calculate an in vitro score:
In vitro irritancy score (IVIS) = mean opacity value + (15 x mean OD490 value)
- Additionally the opacity and permeability values were evaluated independently to determine whether the test item induced irritation through only one of the two endpoints.
The IVIS cut-off values for identifying the test items as inducing serious eye damage (UN GHS Category 1) and test items not requiring classification for eye irritation or serious eye damage (UN GHS No Category) are given in the table in ‘Any other information on materials and methods incl. tables’.
Results and discussion
In vitro
Resultsopen allclose all
- Irritation parameter:
- cornea opacity score
- Run / experiment:
- Mean opacity
- Value:
- -1.5
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Irritation parameter:
- fluorescein leakage
- Run / experiment:
- mean permeability
- Value:
- 0.016
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Irritation parameter:
- in vitro irritation score
- Run / experiment:
- mean in vitro irritation score
- Value:
- -1.3
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Other effects / acceptance of results:
- OTHER EFFECTS:
- The corneas were clear after the 10 minutes of treatment with the test item.
- No pH effect of the test item was observed on the rinsing medium.
ACCEPTANCE OF RESULTS:
- Acceptance criteria for negative control are met.
- Acceptance criteria for positive control are met.
Applicant's summary and conclusion
- Interpretation of results:
- GHS criteria not met
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.