Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Dec 17, 2014 - Dec 17, 2014
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
EC RUGULATION No 440/2008
Deviations:
no
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
2 min
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

In preliminary screening test, Everlan SL65 ignite for a maximum 2 minutes. The combustion does not propagate 200 nm of the train within the 2 minutes test period.

Interpretation of results:
GHS criteria not met
Conclusions:
According to EU A.10 test method, Everlan SL65 is not considered as highly flammable solids. Therefore, Everlan SL65 was not met GHS criteria.
Executive summary:

The flammability properties of Everlan SL65 was determined according to EC REGULATION No 440/2008 Annex A.10 Flammability (Solids). In preliminary screening test, the test result showed that Everlan SL65 ignite for a maximum 2 minutes. But the combustion does not propagate 200 nm of the train within the 2 minutes test period. Therefore, Everlan SL65 is not considered as highly flammable solids.

Description of key information

Everlan SL65 is not considered as highly flammable solids (EC A.10).

Key value for chemical safety assessment

Flammability:
not classified

Additional information

In preliminary screening test, the test result showed that Everlan SL65 ignite for a maximum 2 minutes. But the combustion does not propagate 200 nm of the train within the 2 minutes test period. Therefore, Everlan SL65 is not considered as highly flammable solids.

Justification for classification or non-classification