Registration Dossier

Administrative data

Endpoint:
flammability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP-study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1991

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
Qualifier:
no guideline followed
Guideline:
EU Method A.12 (Flammability (Contact with Water))
Version / remarks:
Test not conducted. Knowledge from handling the TS on humid air and in water and structural reasons.
Qualifier:
no guideline followed
Guideline:
EU Method A.13 (Pyrophoric Properties of Solids and Liquids)
Version / remarks:
Test not conducted. Knowledge from handling the TS on humid air and in water and structural reasons.
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Remarks on result:
other: A.10 - Preliminary test (40 mm pile): Ignition with a hot platinum wire results in melting of the substance. The molten substance does not sustain a flame. Therefore main test not conducted.
Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
Flammable solid; A.10 - No
Liberates flammable gases in contact with water; A.12 - No
Pyrophoric substance; A.13 - No
Tests A.12 and A.13 not conducted. Knowledge from handling the TS on humid air and in water and structural reasons.