Registration Dossier

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The test has been performed following official guidelines and completely assessed the end point.
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
Qualifier:
according to
Guideline:
other: Directive 92/69/EEC
Deviations:
no
GLP compliance:
no
Test procedure:
burning rate test over 100 mm length
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Interpretation of results:
GHS criteria not met
Conclusions:
The substance is not classified as Flammable.
Executive summary:

Flammability of the substance was assessed by EU Method A.10. described in Regulation num. 440/2008.

The substance did not propagate burning of a 200 mm length of the strip in less than four minutes; burning rate test did not need to be performed.

Description of key information

Non flammable under ignition

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

The tested substance is not a highly flammable solid in the sense of the European Commission Regulation (EC) No. 440/2008, Method A.10.

Justification for classification or non-classification

Flammability of the substance was assessed by EU Method A.10. described in Regulation num. 440/2008.

The substance did not propagate burning of a 200 mm length of the strip in less than four minutes; burning rate test did not need to be performed.