Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
density, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
other: IP 365: Crude petroleum and petroleum products - Determination of density - Oscillating U-tube method
Principles of method if other than guideline:
This International Standard specifies a method for the determination, using an oscillating U-tube density meter, of the density of crude petroleum and related products within the range 600 kg/m3 to 1 100 kg/m3 which can be handled as single-phase liquids at the test temperature and pressure.
GLP compliance:
no
Type of method:
oscillating densitimeter
Key result
Type:
density
Density:
0.977 other: kg/L
Temp.:
15 °C
Conclusions:
The density of this substance is 0.9769 Kg/L at 15ºC.
Executive summary:

The density of this substance was determined with an Oscillation U-tube (method IP365) and was found to be 0.9769 Kg/L at 15ºC.

Endpoint:
density, other
Remarks:
density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Not stated
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: GLP status not known, guideline study, available as unpublished report, limitations in design and/or reporting but otherwise adequate for assessment.
Qualifier:
according to guideline
Guideline:
other: ASTM D4052
Deviations:
not specified
GLP compliance:
not specified
Type of method:
other: Not specified
Key result
Type:
density
Density:
>= 0.926 - <= 1 other: no units reported
Temp.:
20 °C
Conclusions:
The density of the substance CAS no. 68477-54-3 was measured to be 0.926 to 1.000 (no units reported) at 20ºC.
Executive summary:

Data was received from the company reporting density. This data is considered reliable and suitable for use. The density of the substance CAS no. 68477-54-3 was measured to be 0.926 to 1.000 (no units reported) at 20ºC.

Endpoint:
density, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
other: IP 365: Crude petroleum and petroleum products - Determination of density - Oscillating U-tube method
Principles of method if other than guideline:
This International Standard specifies a method for the determination, using an oscillating U-tube density meter, of the density of crude petroleum and related products within the range 600 kg/m3 to 1 100 kg/m3 which can be handled as single-phase liquids at the test temperature and pressure.
GLP compliance:
no
Type of method:
oscillating densitimeter
Key result
Type:
density
Density:
0.93 other: kg/L
Temp.:
15 °C
Conclusions:
The density of this substance is 0.9301 Kg/L at 15ºC.
Executive summary:

The density of this substance was determined with an Oscillation U-tube (method IP365) and was found to be 0.9301 Kg/L at 15ºC.

Endpoint:
density, other
Remarks:
density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: GLP status not known, guideline study, available as unpublished report, limitations in design and/or reporting but otherwise adequate for assessment.
Qualifier:
according to guideline
Guideline:
other: DIN 51757
GLP compliance:
not specified
Type of method:
other: Not stated
Key result
Type:
density
Density:
>= 0.902 - <= 0.952 other: g/ml
Temp.:
20 °C
Remarks on result:
other: Result for RÜTGERS 02, RÜTGERS 04, RÜTGERS 05, RÜTGERS 06, RÜTGERS 07 and RÜTGERS 08
Conclusions:
The density of the substance CAS no. 68477-54-3 was measured to be 0.902 g/mL to 0.952 g/mL at 20ºC.
Executive summary:

Data was received from the company reporting density. This data is considered reliable and suitable for use. The density of the substance CAS no. 68477-54-3 was measured to be 0.902 g/mL to 0.952 g/mL at 20ºC.

Endpoint:
relative density
Remarks:
Other density types indicated: density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
30/04/2007
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: GLP, guideline study, available as unpublished report, acceptable with restrictions
Principles of method if other than guideline:
Density according to ASTM D 1298
Relative density at 60/60°C according to ASTM D 1298/D 1250
GLP compliance:
yes (incl. QA statement)
Type of method:
other: no data
Key result
Type:
relative density
Density:
0.894
Temp.:
60 °F
Key result
Type:
density
Density:
0.893 other: kg/l
Temp.:
15 °C
Conclusions:
The relative density of 68477-54-3 is reported to be 0.8936 at 60°F.
Executive summary:

This is a guideline study considered adequate for assessment. The relative density of 68477-54-3 is reported to be 0.8936 at 60°F.

Endpoint:
density, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
other: IP 365: Crude petroleum and petroleum products - Determination of density - Oscillating U-tube method
Principles of method if other than guideline:
This International Standard specifies a method for the determination, using an oscillating U-tube density meter, of the density of crude petroleum and related products within the range 600 kg/m3 to 1 100 kg/m3 which can be handled as single-phase liquids at the test temperature and pressure.
GLP compliance:
no
Type of method:
oscillating densitimeter
Key result
Type:
density
Density:
0.972 other: kg/L
Temp.:
15 °C
Conclusions:
The density of this substance is 0.9715 Kg/L at 15ºC.
Executive summary:

The density of this substance was determined with an Oscillation U-tube (method IP365) and was found to be 0.9715 Kg/L at 15ºC.

Endpoint:
density, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
other: IP 365: Crude petroleum and petroleum products - Determination of density - Oscillating U-tube method
Principles of method if other than guideline:
This International Standard specifies a method for the determination, using an oscillating U-tube density meter, of the density of crude petroleum and related products within the range 600 kg/m3 to 1 100 kg/m3 which can be handled as single-phase liquids at the test temperature and pressure.
GLP compliance:
no
Type of method:
oscillating densitimeter
Key result
Type:
density
Density:
0.914 other: kg/L
Temp.:
15 °C
Conclusions:
The density of this substance is 0.9138 Kg/L at 15ºC.
Executive summary:

The density of this substance was determined with an Oscillation U-tube (method IP365) and was found to be 0.9138 Kg/L at 15ºC.

Endpoint:
density, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
other: IP 365: Crude petroleum and petroleum products - Determination of density - Oscillating U-tube method
Principles of method if other than guideline:
This International Standard specifies a method for the determination, using an oscillating U-tube density meter, of the density of crude petroleum and related products within the range 600 kg/m3 to 1 100 kg/m3 which can be handled as single-phase liquids at the test temperature and pressure.
GLP compliance:
no
Type of method:
oscillating densitimeter
Key result
Type:
density
Density:
0.98 other: kg/L
Temp.:
15 °C
Conclusions:
The density of this substance is 0.9799 Kg/L at 15ºC.
Executive summary:

The density of this substance was determined with an Oscillation U-tube (method IP365) and was found to be 0.9799 Kg/L at 15ºC.

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
30/04/2007
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: GLP, guideline study, available as unpublished report, acceptable with restrictions
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
GLP compliance:
yes (incl. QA statement)
Type of method:
oscillating densitimeter
Key result
Type:
relative density
Density:
0.94 g/cm³
Temp.:
20 °C

2 determinations

Conclusions:
Relative density of C9 - Schnitt (Bl 14002) is D420 = 0.9434 g/cm3.
Executive summary:

This is a GLP compliant, guideline study considered adequate for assessment. Relative density of C9 - Schnitt (Bl 14002) is D420 = 0.9434 g/cm3.

Endpoint:
density, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
other: IP 365: Crude petroleum and petroleum products - Determination of density - Oscillating U-tube method
Principles of method if other than guideline:
This International Standard specifies a method for the determination, using an oscillating U-tube density meter, of the density of crude petroleum and related products within the range 600 kg/m3 to 1 100 kg/m3 which can be handled as single-phase liquids at the test temperature and pressure.
GLP compliance:
no
Type of method:
oscillating densitimeter
Key result
Type:
density
Density:
0.954 other: kg/L
Temp.:
15 °C
Conclusions:
The density of this substance is 0.9542 Kg/L at 15ºC.
Executive summary:

The density of this substance was determined with an Oscillation U-tube (method IP365) and was found to be 0.9542 Kg/L at 15ºC.

Endpoint:
density, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
other: IP 365: Crude petroleum and petroleum products - Determination of density - Oscillating U-tube method
Principles of method if other than guideline:
This International Standard specifies a method for the determination, using an oscillating U-tube density meter, of the density of crude petroleum and related products within the range 600 kg/m3 to 1 100 kg/m3 which can be handled as single-phase liquids at the test temperature and pressure.
GLP compliance:
no
Type of method:
oscillating densitimeter
Key result
Type:
density
Density:
0.973 other: kg/L
Temp.:
15 °C
Conclusions:
The density of this substance is 0.9726 Kg/L at 15ºC.
Executive summary:

The density of this substance was determined with an Oscillation U-tube (method IP365) and was found to be 0.9726 Kg/L at 15ºC.

Endpoint:
density, other
Remarks:
other: not reported
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: GLP unknown, guideline study, available as statement letter from registrant, acceptable with restrictions
Qualifier:
according to guideline
Guideline:
other: DIN 51757
GLP compliance:
not specified
Type of method:
other: not reported
Key result
Type:
other: not reported
Density:
0.972 other: g/ml
Temp.:
20 °C

no further details

Conclusions:
The density of Cas No 101316 -62-5 was determined as 0.972 g/mL at 20 Degs C.
Executive summary:

Information was provided by individual companies in the form of a letter stating the relevant information. The letter was submitted in company’s headed paper and signed by the individual responsible for the area of work. Given that the companies have practical expertise in handling the substance/stream this was deemed to be acceptable information. The density of Cas No 101316-62-5 was determined as 0.972 g/mL at 20 Degrees C.

Endpoint:
density, other
Remarks:
other: not reported
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: GLP unknown, guideline study, available as statement letter from registrant, acceptable with restrictions
Qualifier:
according to guideline
Guideline:
other: DIN 51757
GLP compliance:
not specified
Type of method:
other: not reported
Key result
Type:
other: not reported
Density:
0.96 other: not reported
Temp.:
20 °C

no further details

Conclusions:
The density of Cas No 101316-62-5 was determined as 0.963 at 20 Degs C.
Executive summary:

Information was provided by individual companies in the form of a letter stating the relevant information. The letter was submitted in company’s headed paper and signed by the individual responsible for the area of work. Given that the companies have practical expertise in handling the substance/stream this was deemed to be acceptable information. The density of Cas No 101316-62-5 was determined as 0.963 at 20 Degrees C.

Description of key information

Density data are available for 7 streams (13 studies) within this category ranging from 0.894 to 1.000.

Key value for chemical safety assessment

Relative density at 20C:
0.945

Additional information

The density values for streams in this category have been taken from lead-registrant data, proprietary data and certificates of analysis. The data will be read across to all category members.

Lead-registrant data (Intertek, 2018):

EC 266 -013 -0 (CAS#65996-79 -4): 0.9769 Kg/L;

EC 270 -737 -2 (CAS#68477-54-3): 0.9301 Kg/L;

EC 270 -790 -1 (CAS#68478-10-4): 0.9715 Kg/L;

EC 271 -138 -9 (CAS#68516-20-1): 0.9138 Kg/L;

EC 271 -213 -6 (CAS#68526-56-7): 0.9799 Kg/L;

EC 305 -586 -4 (CAS#94733-07-0): 0.9542 Kg/L;

EC 309 -867 -2 (CAS#101316-62-5): 0.9726 Kg/L.

Proprietary data:

CAS# 94733-07-0: 0.94 g/cm3 at 20°C (BASF, 2007a);

CAS# 101316-62-5: 0.96 (no unit) and 0.972 g/mL at 20°C (TS&D Rutgers Germany 2010b, c);

CAS# 68477-54-3 range 0.902 - 0.952 g/mL at 20°C (RÜTGERS 2010a, 2010b, 2010c), 0.926 - 1.000 (no units reported) (Dow Benelux 2010b), 0.8936 at 15.6°C (SIBUR, 2009).

The mean of the density values for the category is 0.945 (unitless) and this value has been used to complete the 'key value for the safety assessment'.