Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009/04/06
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Test procedure in accordance with national standard methods (ASTM) without GLP.
Qualifier:
according to guideline
Guideline:
other: ASTM D446/07
Deviations:
no
GLP compliance:
no
Type of method:
capillary viscometer (static)
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
20.03
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
9.98

CALIBRATION

SUBSTANCE USED FOR CALIBRATION: 1-Octanol NQS08003

CALIBRATION TEMPERATURE: 25.0 °C / 25.0 °C

KINEMATIC VISCOSITY (THEORY) : 8.84 mm2/s / 8.84 mm2/s

VISCOSIMETER CONSTANT: 0.05012 / 0.05012

MEASURED FLOW TIME: 176.8 sec / 176.6 sec

KINEMATIC VISCOSITY (EXPERIMENTAL): 8.86 mm2/s / 8.85 mm2/s

MEASUREMENT

(repeat determination)

TEMPERATURE: 20.0 °C / 20.0 °C (40 °C / 40 °C)

VISCOSIMETER CONSTANT: 0.05012 / 0.05012 (0.05012 / 0.05012)

MEASURED FLOW TIME: 399.2 sec / 400.24 sec (199.03 sec / 199.09 sec)

KINEMATIC VISCOSITY: 20.01 mm2/s / 20.06 mm2/s (9.97 mm2/s / 9.98 mm2/s)

KINEMATIC VISCOSITY AVERAGE: 20.03 mm2/s (9.98 mm2/s)

Conclusions:
Kinematic viscosity of undecan-1-ol: at 20 °C: 20.03 mm²/s and at 40 °C: 9.98 mm²/s.
 
Executive summary:

Viscosity of undecan-1 -ol at 20 °C

Analysis No  Kinematic viscosity [mm²/s]  Temperature [°C]
 1  20.01  20.0
 2  20.06  20.0
 Mean  20.03  

Viscosity of undecan-1 -ol at 40 °C

Analysis No  Kinematic viscosity [mm²/s]  Temperature [°C]
 1  9.97  40.0
 2  9.98  40.0
 Mean  9.98  
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Test procedure in accordance with national standard methods (ASTM) without GLP.
Qualifier:
according to guideline
Guideline:
other: ASTM D446/07
Deviations:
no
GLP compliance:
no
Type of method:
capillary viscometer (static)
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
ca. 18.64
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
ca. 9.72

CALIBRATION

(repeat determination)

SUBSTANCE USED FOR CALIBRATION:1-Octanol NQS08003

CALIBRATION TEMPERATURE:25.0 °C / 25.0 °C

KINEMATIC VISCOSITY (THEORY):8.84 mm²/s / 8.84 mm²/s

VISCOSIMETER CONSTANT:0.05012 / 0.05012

MEASURED FLOW TIME:176.8 sec / 176.6 sec

KINEMATIC VISCOSITY (EXPERIMENTAL):8.86 mm²/s / 8.85 mm²/s

MEASUREMENT

(repeat determination)

TEMPERATURE:20.0 °C / 20.0 °C (40 °C / 40 °C)

VISCOSIMETER CONSTANT:0.05012 / 0.05012 (0.05012 / 0.05012)

MEASURED FLOW TIME: 371.7 sec / 372.1 sec (194.2 sec / 193.8 sec)

KINEMATIC VISCOSITY: 18.63 mm²/s / 18.65 mm²/s (9.73 mm²/s / 9.71 mm²/s)

KINEMATIC VISCOSITY AVERAGE: 18.64 mm²/s (9.72 mm²/s)

Executive summary:

Viscosity at 20 °C

Analysis No  Kinematic viscosity [mm²/s]  Temperature [°C]
 1  18.63  20.00
 2  18.65  20.00
 Mean  18.64  

Viscosity at 40 °C

Analysis No  Kinematic viscosity [mm²/s]  Temperature [°C]
 1  9.73  40.00
 2  9.71  40.00
 Mean  9.72  

Description of key information

The kinematic viscosity of undecan-1-ol is  20.03 mm2/s at 20°C.

Key value for chemical safety assessment

Viscosity:
20.03 mm²/s (static)
at the temperature of:
20 °C

Additional information

The kinematic viscosity of 20.03 mm2/s was determined for undecan-1 -ol with the use of a capillary method in accordance with ASTM D446. The result is considered to be reliable.

It is supported by a value of 9.98 mm2/s at 40°C in a second determination from the same test.

Discussion of trends in the Category of C6-24 linear and essentially-linear aliphatic alcohols:

As chain length increases, kinematic viscosity increases. This is because molecular weight is higher and intermolecular forces in the substance are all higher.