Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
other: Eraflash flash-point tester (Eralytics)

Test material

Constituent 1
Chemical structure
Reference substance name:
Reaction products of diphenyl ether and 9-methylene nonadecane
EC Number:
943-303-1
Molecular formula:
Variable, substance is a UVCB
IUPAC Name:
Reaction products of diphenyl ether and 9-methylene nonadecane
Test material form:
liquid

Results and discussion

Flash point
Flash point:
242 °C
Atm. press.:
101.3 kPa

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The closed cup method was applied for the determination of the flash-point of the test substance. The flash-point of the test item was 242°C.