Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 25 April 2017 to 28 April 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
yes (incl. certificate)
Type of method:
effusion method: Knudsen cell

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent
Type:
Constituent
Test material form:
liquid

Results and discussion

Vapour pressureopen allclose all
Key result
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
0.422 Pa
Test no.:
#2
Temp.:
25 °C
Vapour pressure:
0.567 Pa

Applicant's summary and conclusion

Conclusions:
For the test item SINODOR CQ, the following vapour pressures at 20°C and 25 °C were calculated from the regression equation:
Vapour Pressure at 20°C : 0.422 Pa
Vapour Pressure at 25°C : 0.567 Pa