Registration Dossier

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From March 08, 2017 to March 22,2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
OECD Guideline 103 (Boiling Point)
Qualifier:
according to
Guideline:
EU Method A.2 (Boiling Temperature)
GLP compliance:
yes (incl. certificate)
Type of method:
other: method of the capillarity tube

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent
Type:
Constituent
Test material form:
liquid

Results and discussion

Boiling point
Key result
Boiling pt.:
305 °C
Atm. press.:
1 013 hPa
Decomposition:
no

Applicant's summary and conclusion

Conclusions:
It can be concluded that the standard boiling point of SINODOR CQ is (values rounded off):
578 K (305°C)

Executive summary:

The boiling point of SINODOR CQ was measured according to OECD guideline No.103 (method of capillarity tube).

The result can be expressed as followed (values rounded off):

Boiling point of SINODOR CQ: 578 K (305°C)