Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From January 10,2017 to February 03,2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes (incl. certificate)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent
Type:
Constituent
Test material form:
liquid

Results and discussion

Flash point
Key result
Flash point:
192.5 °C
Atm. press.:
101 325 Pa

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The results of the main tests are:
First determination: Flash point, corrected for atmospheric pressure: 193.0°C
Second determination: Flash point, corrected for atmospheric pressure: 192.0°C
The results of the two tests were averaged and rounded off to the nearest 0.5°C to obtain the final flash point value:
Flash point SINODOR CQ: 192.5 °C.
Executive summary: