Registration Dossier

Diss Factsheets

Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009-06-30
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Determination has been run according to standardized method but without GLP compliance.
Qualifier:
according to guideline
Guideline:
other: ASTM E 537 – 07
Deviations:
no
GLP compliance:
no
Type of method:
other: differential scanning calorimetry
Atm. press.:
ca. 101 325 Pa
Remarks on result:
other: The melting point can not be found within the temperature range -30-300 ºC.

The melting point can not be found within the temperature range -30-300 ºC.

Conclusions:
The melting point can not be found within the temperature range -30-300 ºC.

Description of key information

Key value for chemical safety assessment

Melting / freezing point at 101 325 Pa:
-30 °C

Additional information

The melting point can not be found within the temperature range -30-300 ºC.