Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
GLP compliance:
yes (incl. certificate)
Type of method:
gas saturation method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid

Results and discussion

Vapour pressure
Key result
Temp.:
20 °C
Vapour pressure:
1 Pa

Applicant's summary and conclusion

Conclusions:
The vapour pressure of the test material GR-50-3010 has been determined to be 1.0 Pa at 20°C using the gas saturation method.

Therefore:
Vapour pressure of GR-50-3010: 1.0 Pa at 20°C.