Registration Dossier

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
GLP compliance:
yes (incl. certificate)
Type of method:
other: densimeter method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid

Results and discussion

Density
Key result
Type:
relative density
Density:
0.856 g/cm³
Temp.:
20 °C

Applicant's summary and conclusion

Conclusions:
The density of GR-50-3010 was determined according to the OECD guideline No. 109 (oscillating densitimeter method). The result can be expressed as follows:

d = 0.856 ± 0.001 g/ml at 20°C
or D 420 = 0.856 ± 0.001

Executive summary:

The density of GR-50-3010 was determined according to the OECD guideline No. 109 (oscillating densitimeter method). The result can be expressed as follows:

 

                       d = 0.856±0.001 g/ml at 20°C

or                   D420= 0.856±0.001