Registration Dossier

Administrative data

Endpoint:
surface tension
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 115 (Surface Tension of Aqueous Solutions)
GLP compliance:
yes (incl. certificate)
Type of method:
ring method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid

Results and discussion

Surface tension
Key result
Surface tension:
40.8 mN/m
Temp.:
20 °C
Conc.:
90.4 mg/L

Applicant's summary and conclusion

Conclusions:
The result is:  40.8 mN/m
Executive summary:

The surface tension of a solution of GR-50-3010 in ultrapure water (90.4 mg/l, ~90% of the saturation concentration) was determined according to the OECD Guideline No. 115, using the ring method.

 

The result is:           40.8 mN/m

 Therefore, according to this test, it was considered that the test material is surface active (surface tension < 60 mN/m).