Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Justification for type of information:
The data is from reliable sources.
Qualifier:
according to guideline
Guideline:
other: Sieve Method
Principles of method if other than guideline:
Determination of Particle size distribution of test substances
GLP compliance:
no
Type of method:
other: Sieve method
Type of particle tested:
agglomerate
Type of distribution:
volumetric distribution
Mass median aerodynamic diameter:
>= 53 - <= 150 µm
Key result
Percentile:
D50
Mean:
150 µm
St. dev.:
14.78
Key result
Percentile:
D50
Mean:
106 µm
St. dev.:
51.07
Key result
Percentile:
D50
Mean:
75 µm
St. dev.:
25.73
Key result
Percentile:
D50
Mean:
53 µm
St. dev.:
8.42
Conclusions:
The particle size distribution of test substance was determined by granulometric analysis . The particle size distribution was determined to be in the range of 150 micron to 53 micron.
Executive summary:

On basis of study report ,The particle size distribution of test substance was determined by granulometric analysis. The particle size distribution was determined to be in the range of 150 micron to 53 micron.

Description of key information

The particle size distribution of Phenethyl Salicylate was determined by granulometric analysis. The particle size distribution was determined to be in the range of 150 micron to 53 micron.

Additional information

The particle size distribution of Phenethyl Salicylate was determined by granulometric analysis. The particle size distribution was determined to be in the range of 150 micron to 53 micron.