Registration Dossier

Diss Factsheets

Environmental fate & pathways

Biodegradation in water: screening tests

Currently viewing:

Administrative data

Endpoint:
biodegradation in water: ready biodegradability
Type of information:
experimental study
Adequacy of study:
key study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1997
Report date:
1997

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method C.4-B (Determination of the "Ready" Biodegradability - Modified OECD Screening Test)

Test material

Study design

Inoculum or test system:
other:
Duration of test (contact time):
28 d
Initial test substance concentrationopen allclose all
Initial conc.:
1 g/L
Based on:
test mat.
Initial conc.:
19.8 mg/L
Based on:
DOC

Results and discussion

% Degradation
Parameter:
% degradation (DOC removal)
Value:
79
Sampling time:
28 d

Applicant's summary and conclusion

Validity criteria fulfilled:
yes