Reference
Endpoint:
flammability, other
Remarks:
Lower Explosion Limit
Type of information:
experimental study
Adequacy of study:
key study
Study period:
December 2016
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
no guideline followed
Principles of method if other than guideline:
Flammability test is not applicable to a chlorinated liquid. A Lower Explosion Limit was performed instead.

GLP compliance:
no

Injected sample quantities ranging from 0.01 g to 5.0 g produced no explosion. It is concluded than no lower explosive limit exists for this material.

Interpretation of results:
GHS criteria not met
Conclusions:
Injected sample quantities ranging from 0.01 g to 5.0 g produced no explosion. It is concluded that no Lower Explosive Limit exists for this material. The test item did not meet the criteria for classification according to Regulation (EC) No.1272/2008 on the Classification, Labelling and Packaging of Substances and Mixtures.
Executive summary:

Considering that the flammability is not applicable for a chlorinated liquid, the Lower Explosion Limit of the substance was evaluated. Injected sample quantities ranging from 0.01 g to 5.0 g produced no explosion. It was concluded that no Lower Explosive Limit exists for this material. The test item did not meet the criteria for classification according to Regulation (EC) No.1272/2008 on the Classification, Labelling and Packaging of Substances and Mixtures.

Description of key information

Considering that the flammability is not applicable for a chlorinated liquid, the Lower Explosion Limit of the substance was evaluated. Sample quantities ranging from 0.01 g to 5.0 g produced no explosion. It was concluded that no Lower Explosive Limit exists for this material. The test item did not meet the criteria for classification as a flammable liquid according to Regulation (EC) N° 1272/2008.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification