Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016-09-20 to 2016-09-21
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Version / remarks:
2004
Deviations:
yes
Remarks:
Due to technical reasons, standards were injected seperately instead of simultaneously
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient - HPLC Method)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
4.36
Temp.:
22.7 °C
Remarks on result:
other: mean of 2 injections and 2 calibrations, more info in "Any other information on results".

The retention times for the reference items are given below:

Reference item log Pow 1st calibration 2nd calibration
retention time k  log k retention time k  log k
Anisole 2.1 2.498 4.09 0.612 2.508 4.11 0.614
Allyl phenyl ether 
2.9 3.752 6.64 0.822 3.769 6.68 0.825
Ethylbenzene 
3.2 5.278 9.75 0.989 5.299 9.79 0.991
Isopropylbenzene 
3.7 7.071 13.4 1.127 7.104 13.5 1.130
n-Butylbenzene 
4.6 12.127 23.7 1.375 12.175 23.8 1.377
Fluoranthene 
5.1 14.667 28.9 1.461 14.71 29 1.462
Triphenylamine 
5.7 21.954 43.7 1.640 22.067 43.9 1.642

The void time was found to be 0.491 on average (n=3).

The R2 values for the calibration are > 0.99

The details on the measurement of the test sample are:

log Pow
retention time k  log k 1st calibration 2nd calibration
9.813 19 1.279 4.37 ± 0.05 4.36 ± 0.06
9.826 19 1.279
9.82 19 1.279 4.36
Conclusions:
The test item has a log Pow value of 4.36.
Executive summary:

The partition coefficient of the test substance was determined according to OECD 117, HPLC method. For the calibration, 7 reference plus sodium nitrate for the void time were injected. Two valid calibration curves were set up. A solution of 3000 mg/L test item was prepared and injected twice. The average log Pow value was found to be 4.36.

Description of key information

For this endpoint, one study is available assessing the octanol-water partition coefficient of the test item. This study was performed according to OECD 117, HPLC method. The log Pow value of the test item was found to be 4.36.

Key value for chemical safety assessment

Log Kow (Log Pow):
4.36
at the temperature of:
22.7 °C

Additional information