Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
June 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent
Type:
impurity
Type:
impurity
Type:
impurity
Type:
impurity
Test material form:
liquid
Details on test material:
UVCB substance

Results and discussion

Flash point
Key result
Flash point:
121 °C
Atm. press.:
101 325 Pa

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Executive summary:

The flash point of Jasmonyl LG was determined by the Pensky-Martens method according to ISO 2719.

The result is: 121.0oC