Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Non GLP study according to OECD 104

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2010
Report Date:
2010

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
no
Type of method:
dynamic method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
other: liquid

Results and discussion

Vapour pressure
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
ca. 0.07 mBar

Applicant's summary and conclusion

Conclusions:
The vapour pressure 0.07 mbar at 1.013 bar at 20°C