Administrative data

Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental starting date: 12 June 2016 Experimental completion date: 01 July 2016
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
O,O-dibutyl hydrogen thiophosphate, compound with 1-octylamine (1:1)
EC Number:
300-947-2
EC Name:
O,O-dibutyl hydrogen thiophosphate, compound with 1-octylamine (1:1)
Cas Number:
93964-99-9
Molecular formula:
C8H19N.C8H19O3PS
IUPAC Name:
octan-1-amine dibutyl sulfanylphosphonate
impurity 1
Chemical structure
Reference substance name:
Octylamine
EC Number:
203-916-0
EC Name:
Octylamine
Cas Number:
111-86-4
Molecular formula:
C8H19N
IUPAC Name:
octan-1-amine
Test material form:
liquid
Specific details on test material used for the study:
Information as provided by the Sponsor. The Certificate of Analysis provided by the Sponsor is presented as Annex 2 (Please see Attachment Section of this Summary).

Identification: X-19575 Phosphorothioic acid, O,O-dibutyl ester, compd. with 1-octanamine, CASRN 93964-99-9
Appearance/Physical state: amber colored viscous liquid
Batch: X-019575-00-00
Purity: UVCB Substance (treat as 100%)
Expiry date: 01 June 2017
Storage conditions: room temperature, in the dark

Results and discussion

Flash point
Flash point:
93 °C
Atm. press.:
99.8 kPa

Any other information on results incl. tables

Results

Results of the flash point determination are shown in the following table:

Table 1

Test Temperature (ºC)

Observations

21.0

No flash.

26.0

No flash.

31.0

No flash.

36.0

No flash.

41.0

No flash.

46.0

No flash.

51.0

No flash.

56.0

No flash.

61.0

No flash.

66.0

No flash.

71.0

No flash.

71.0 (fresh sample)

No flash.

76.0

No flash.

81.0

No flash.

86.0

No flash.

91.0

No flash.

96.0

No flash.

101.0 (fresh sample)

An orange flash spread across the sample cup.

101.0 (fresh sample)

An orange flash spread across the sample cup.

96.0 (fresh sample)

An orange flash spread across the sample cup.

91.0 (fresh sample)

No flash.

92.0 (fresh sample)

No flash.

93.0 (fresh sample)

An orange flash spread across the sample cup.

93.0 (fresh sample)

An orange flash spread across the sample cup.

91.0 (fresh sample)

No flash.

Atmospheric pressure: 99.8 kPa

Corrected flash point: 93.4 ºC

Applicant's summary and conclusion

Conclusions:
The flash point of the test item has been determined to be 93 ± 2 °C.
Executive summary:

The determination was carried out using a closed cup flash point tester*, using a procedure designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008.


*Based on, Anon (1983) Paints, Varnishes, Petroleum and Related Products – Determination of Flash Point – Rapid Equilibrium Method,International Standard ISO 3679-2004 (E),Second Edition –2004-04-01,P1-18and Anon (1989) Flash Point of Liquids by Setaflash Closed-Cup Apparatus,ASTM D-3278-89,P1-7.

Conclusion

The flash point of the test item has been determined to be 93 ± 2 °C.