Registration Dossier

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
density, other
Remarks:
density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
24 February 2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Only a 2 page study summary, though the critical information for this endpoint is included.
Remarks:
Conducted according to GLP
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
GLP compliance:
yes
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
air comparison pycnometer (for solids)
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 2017/02
- Expiration date of the lot/batch: No data
- Purity test date: No data

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: No data
- Stability under test conditions: No data
- Solubility and stability of the test substance in the solvent/vehicle: No data
- Reactivity of the test substance with the solvent/vehicle of the cell culture medium: No data

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: No data
- Final dilution of a dissolved solid, stock liquid or gel: No data
- Final preparation of a solid: No data
Dynamic viscosity of test material:
No data
Key result
Type:
density
Density:
2.705 g/cm³
Temp.:
20 °C

 Test number    1  2
 Mass/g    2.2683  2.1284
 Temperature/°C  Run  19.98  20.03
 Volume/cm3  0.8358  0.7894
   2  0.8353  0.7891
   3  0.8362  0.7888
   4  0.8373  0.7899
   5  0.8364  0.7896
 Average volume/cm3    0.8362  0.7894
 Density/gcm-3    2.7126  2.6964
Conclusions:
The density of tetraammineplatinum(II) hydrogen carbonate at 20 °C was determined to be 2.705 g/cm3.

Executive summary:

In a guideline study, conducted to GLP, the density of tetraammineplatinum(II) hydrogen carbonate was determined by the pycnometer method to be 2.705 g/cm3 at a temperature of 20 °C.

Description of key information

The density of tetraammineplatinum(II) hydrogen carbonate at 20 °C was determined to be 2.705 g/cm3 (Mekelburger, 2017a).

Key value for chemical safety assessment

Relative density at 20C:
2.705

Additional information

Categories Display