Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
October 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
Methyl oct-2-ynoate
EC Number:
203-836-6
EC Name:
Methyl oct-2-ynoate
Cas Number:
111-12-6
Molecular formula:
C9H14O2
IUPAC Name:
methyl oct-2-ynoate
Test material form:
liquid

Results and discussion

Flash point
Key result
Flash point:
96.5 °C
Atm. press.:
101 325 Pa

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Executive summary:

The results of the main tests were:

First determination: Flash point corrected for atmospheric pressure: 97.0oC

Second determination: Flash point corrected for atmospheric pressure: 96oC

As teh results of the two determinations did not differ by more than 2.0oC, it was not necssary to run a third determination.

The results of the two tests were averaged and rounded off to the nearest 0.5oC to obtain the final flash point value: 96.5oC.

Categories Display