Registration Dossier

Administrative data

Endpoint:
flammability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report Date:
2016

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: VDI 2263 sheet 1
GLP compliance:
no

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: particulate/powder

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Burning time:
> 1 000 s

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
Combustion Number 2 can be assigned to the substance: no ignition
The substance does not have to be classified as a “readily combustible solid”, class 4.1, of the transport regulations.
The substance does not have to be classified as a “flammable solid” according to EU-GHS/CLP.
The substance does not have to be classified as a “highly flammable solid” according to EG 440/2008.
Executive summary:

The substance was tested for flammability according to VDI 2263 sheet 1.

At ambient temperature the product burned locally with a flame during the ignition source (flame or hot wire) was applied. When the ignition source was removed the combustion extinguished. A propagation of the combustion was not observed. The product did not melt. The combustion behaviour of the product at ambient temperature is characterized by the burning index BZ 2 (brief ignition and rapid extinction). Due to the fact that no propagation of the combustion was observed the burning rate had not to be determined.