Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
activated sludge respiration inhibition testing
Type of information:
other: read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
key study
Study period:
From August 12, 1993 to August 18, 1993
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
Deviations:
yes
Remarks:
preparation of the inoculum: higher sludge weight after the washing procedure (sludge concentration in the test according to the guidelines); 4 instead of 5 test conc.
Principles of method if other than guideline:
SAV: 05 000 02
GLP compliance:
yes (incl. QA statement)
Analytical monitoring:
no
Details on sampling:
No data
Vehicle:
yes
Details on test solutions:
Since the test substance swam at the surface of the medium, the stock solution was prepared by adding one drop of the emulsifier Tween 80 (concentration 35.2 mg/L). The highest solvent concentration used in the test (22.53 mg/L) was additionally tested as solvent control.
Test organisms (species):
activated sludge, domestic
Details on inoculum:
Activated sludge from ARA Pro Rheno Basel (communal sewage treatment plant).
Pretreated by washing 3 times with tap water and addition of synthetic sewage (one day before main test).
Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
3 h
Remarks on exposure duration:
None
Post exposure observation period:
No data
Hardness:
No data
Test temperature:
20.9 °C

pH:
7.9-8.1
Dissolved oxygen:
No data
Salinity:
No data
Nominal and measured concentrations:
Nominal concentrations: 0, 10, 32, 100 and 320 mg/L

Details on test conditions:
Sludge dry weight: 1.5 g/L
Test volume: 100 mL
Estimation technique: O2-consumption, measured with an oxygen sensitive electrode system: OXI DIGI 530 (SAV: 00 109)
Aeration: 0.1 - 0.2 L/min by pasteur-pipette
pH of sludge: 7.6 before the test beginning


Reference substance (positive control):
yes
Remarks:
(3,5-dichlorophenol)
Duration:
3 h
Dose descriptor:
IC50
Effect conc.:
> 320 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Results with reference substance (positive control):
- Results with reference substance valid
- Relevant effect levels: 3h IC50 = 13.5 mg/L

Results:

Control

pH

after

3h

1)

O2-consumption

(in cm)

2) time

(in cm)

mg O2 / min/L

Legend:

C =Control;

1) 2 cm=0.8 mg/L O2;

2) 2 cm= 1 minute

C1

C2

8.1

8.0

4.6

4.5

3.7

3.8

0.99

0.95

ΦC 0.97

C1/C2 : 4.21%

C2/C2 : 4.04%

 

Test substance(mg/L)

pH

after

3h

1)

O2-consumption

(in cm)

2) time

(in cm)

mg O2

pro minute/L

%

of control

%

inhibition

320

7.9

4.9

4.1

0.96

98.97

1.03

100

8.0

4.7

4.0

0.94

96.91

3.09

32

8.0

4.8

4.1

0.94

96.91

3.09

10

8.1

4.5

3.8

0.95

97.94

2.06

 

3,5-

Dichlorophenol

(mg/L)

pH

after

3h

1)

O2-consumption

(in cm)

2) time

(in cm)

mg 0 2

pro minute/L

%

of control

%

inhibition

32

8.2

1.2

5.6

0.17

17.53

82.47

10

8.1

3.7

5.0

0.59

80.82

39.18

3.2

8.1

4.4

4.2

0.84

86.60

13.40

Validity criteria fulfilled:
yes
Conclusions:
Under the test conditions, the IC50 of the test substance was determined to be > 320 mg/L (i.e. > 290 mg a.i./L). The 3 h IC50 for the reference substance was 13.5 mg/L.


Executive summary:

A study was conducted to determine the toxicity of the test substance to activated sludge according to OECD Guideline 209 in compliance with GLP.

Sludge from a domestic wastewater treatment plant was exposed for 3 h at 0, 10, 32, 100 and 320 mg/L. The reference substance 3 -5, dichlorophenol was also tested at 3.2, 10 and 32 mg/l.

Under the study conditions, the 3 h IC50 was > 320 mg/L (i.e. > 290 mg a.i./L). The 3 h IC50 for the reference substance was 13.5 mg/L.

Description of key information

IC50(3h) > 320 mg/L (i.e. > 290 mg a.i./L)

Key value for chemical safety assessment

EC50 for microorganisms:
290 mg/L

Additional information