Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
December 2016
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
non-equilibrium method closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
181.5 °C
Atm. press.:
ca. 1 atm
Key result
Result:
not sustaining combustion
Interpretation of results:
GHS criteria not met
Conclusions:
The substance 1,2,3-Propanetricarboxylic acid, 2-hydroxy-, tris(1-methyl-C12-13-alkyl) esters shows a Flash point at 181°C at atmospheric pressure
Executive summary:

The substance 1,2,3-Propanetricarboxylic acid, 2-hydroxy-, tris(1-methyl-C12-13-alkyl) esters shows a Flash point at 181°C at atmospheric pressure

Description of key information

Key value for chemical safety assessment

Flash point at 101 325 Pa:
181 °C

Additional information