Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 696-157-3 | CAS number: 57390-39-3
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
- General information Instantly remove any clothing soiled by the product.
- After inhalation Supply fresh air; consult doctor in case of symptoms.
- After skin contact Instantly wash with water and soap and rinse thoroughly.
- After eye contact Rinse opened eye for several minutes (10 - 15)under running water.
- After swallowing Instantly call for doctor.
- 4.2 Most important symptoms and effects, both acute and delayed No further relevant information available.
- 4.3 Indication of any immediate medical attention and special treatment needed
No further relevant information available.
Fire-fighting measures
- Suitable extinguishing agents
CO2, extinguishing powder or water jet. Fight larger fires with water jet or alcohol-resistant foam.
- For safety reasons unsuitable extinguishing agents Do not use a heavy water stream.
- 5.2 Special hazards arising from the substance or mixture
Can be released in case of fire
Carbon monoxide (CO), carbon dioxide (CO2)
Hydrogen chloride (HCl)
Hydrogen fluoride (HF)
- 5.3 Advice for firefighters
- Protective equipment:
Wear self-contained breathing apparatus.
Do not inhale explosion gases or combustion gases.
Wear full protective suit.
- Additional information
Dispose of fire debris and contaminated fire fighting water in accordance with official regulations.
Accidental release measures
Use breathing protection against the effects of fumes/dust/aerosol.
- 6.2 Environmental precautions: Do not allow to enter drainage system, surface or ground water.
- 6.3 Methods and material for containment and cleaning up:
Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders).
Dispose of contaminated material as waste according to item 13.
Ensure adequate ventilation.
Handling and storage
Ensure good ventilation/exhaustion at the workplace.
Prevent formation of aerosols.
- Information about protection against explosions and fires: No special measures required.
- 7.2 Conditions for safe storage, including any incompatibilities
- Storage
- Requirements to be met by storerooms and containers: No special requirements.
- Information about storage in one common storage facility: Not required.
- Further information about storage conditions: Store in cool, dry conditions in well sealed containers.
- 7.3 Specific end use(s) No further relevant information available.
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
- 8.1 Control parameters
- Components with limit values that require monitoring at the workplace: Not required.
- DNELs (Derived no-effect level) No information available
- PNECs (predicted no effect concentration) No information available
- 8.2 Exposure controls
- Personal protective equipment
- General protective and hygienic measures
The usual precautionary measures should be adhered to general rules for handling chemicals.
Keep away from foodstuffs, beverages and food.
Wash hands during breaks and at the end of the work.
Do not inhale fumes
- Breathing equipment:
In case of brief exposure or low pollution use breathing filter apparatus. In case of intensive or longer
exposure use breathing apparatus that is independent of circulating air.
- Recommended filter device for short term use: Filter A (acc. to EN 141) for organic vapours and gases; boiling piont > 65 °C
- Protection of hands: Not required. Use recommended.
- Material of gloves: The selection of the suitable gloves does not only depend on the material, but also on further
marks of quality and varies from manufacturer to manufacturer.
- Penetration time of glove material: The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be
observed.
- Eye protection: Safety glasses
- Body protection: Protective work clothing.
Stability and reactivity
- 10.2 Chemical stability
- Thermal decomposition / conditions to be avoided: No decomposition if used according to specifications.
- 10.3 Possibility of hazardous reactions No dangerous reactions known
- 10.4 Conditions to avoid No further relevant information available.
- 10.5 Incompatible materials:
Strong oxidizing materials
Acids
- 10.6 Hazardous decomposition products:
Hydrogen chloride (HCl) / hydrochloric acid
Fluorinated hydrocarbons
Hydrogen fluoride
Disposal considerations
- Recommendation
After prior treatment product has to be disposed of in an incinerator for hazardous waste under adherence to
the regulations pertaining to the disposal of particularly hazardous waste.
- Uncleaned packagings:
- Recommendation:
Disposal must be made according to official regulations.
Packaging must be disposed of in compliance with country-specific regulations or must be passed to a
packaging return system.
Empty contaminated packagings thoroughly. They can be recycled after thorough and proper cleaning.
Packagings that cannot be cleaned are to be disposed of in the same manner as the product.
15 01 10: packaging containing residues of or contaminated by dangerous substances
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.