Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: guidline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: Fire propagation rate (UN), N1
Principles of method if other than guideline:
Recommendations on the Transport of Dangerous Goods, Manual of Tests and Criteria,
2nd revised edition, Part III, Test N.1, Section 33.2.1.4
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
α-chloro-4-fluoroacetophenone
EC Number:
207-256-4
EC Name:
α-chloro-4-fluoroacetophenone
Cas Number:
456-04-2
Molecular formula:
C8H6ClFO
IUPAC Name:
2-chloro-1-(4-fluorophenyl)ethanone
Test material form:
other: solid
Details on test material:
- Name of test material (as cited in study report): Fluorachloracetophenon QB 063 v. 12.11.09
- Analytical purity: not documented

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Remarks on result:
other: Brief burning followed by rapid extinction
Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Substances / mixtures which in contact with water emit flammable gases
Remarks on result:
no reaction with water observed
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

1. Preliminary test: Burning time ( 200 mm test distance): Brief burning followed by rapid extinction. Therefore, the preliminary screening test is negative. Because of the result of the preliminary test the test substance is not considered a flammable solid of division 4.1.

Applicant's summary and conclusion