Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
no
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks:
burning rate test over 200 mm
Burning time:
0 s
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Interpretation of results:
GHS criteria not met
Conclusions:
the test item could not be ignited with a flame
the test item melted
the test item is not a highly flammable solid

Description of key information

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification